7526 DCT Reference
Note:
The '*' denotes functions which require V2.00 microcode or higher.
.
The stored transaction programs are in records 01-64. Keys
31-56 are not associated with any device, so they can only be activated
through CMD G or by using a Goto (See ":G&mdash.Goto") or
Gosub (":GS&mdash.Gosub") key command.
These records consist of a sequence of transaction
programming key commands terminated by record separator (RS) characters.
Notes:
- The most recent keyboard input, reader input, or DI/DO input is
always stored in user variable 0. This is so it can be processed by CFRs
or following steps in the transaction program.
- A secure record good read from a magnetic stripe is displayed
ONLY as a series of asterisk (*) characters equal in length to
the badge-data length. The secure header information is stripped off
before appending to the transaction record.
A special first character indicates
that a secure header was read (an ASCII 10h, which is the DLE
character) .
(Ref #4.)
- The format of many of the commands were designed for compatibility
between the 7527 and 7525 DCTs resulting in some values and parameters
not being used, although space is reserved for them.
- The Transaction commands are prefaced with a colon (:) or a
semicolon (;).
l.
transaction program commands
- :0&mdash.Display Message from Message File
- :1&mdash.Fixed Length Badge Read with Validation
- :2&mdash.Numeric Keypad Input
- :3&mdash.Alphanumeric Keypad Input.
- :4&mdash.Alphanumeric Keys or Badge Input Expected
- :5&mdash.Set Time-of-Day Clock
- :6&mdash.Display Message
- :7&mdash.Toggle DO Point 0
- :8&mdash.Link Function
- :9&mdash.NO-OP
- :A&mdash.Automatic Transaction Build
- :D&mdash.Delay 1-99 Seconds
- :E&mdash.Show Message
- :F&mdash.Append Data
- :G&mdash.*Goto
- :GS&mdash.*Gosub
- :H&mdash.Clear Selected User Variable
- :J&mdash.*Format User Variable
- :K&mdash.Verify Selected User Variable
- :L&mdash.*Program Label
- :M&mdash.Read Value of DI/DO Point
- :N&mdash.Wait DI Point
- :P&mdash.Write DO Point
- :R&mdash.Read Data with Validation
- :T&mdash.Clear Display
- :U&mdash.Set Cursor Position
- :W&mdash.Write Data from Source to Target
- :Z&mdash.*Onkey Goto
- :ZS&mdash.*Onkey Gosub
- ;0&mdash.Hot Key
- ;1&mdash.Read Variable Length Badge.
- ;2&mdash.Latching Function
- ;5&mdash.Read Display Buffer.
- ;6&mdash.Do Not Transmit
- ;7&mdash.Append Data to User Variable Data Strings
- ;A&mdash.Alias Transaction ID
- ;C&mdash.Activate Selected Operator Indicator
- ;M&mdash.Call CFR
- ;N&mdash.*Test User Variable
- ;R&mdash.*Return from Transaction Program Subroutine
Note:
The '*' denotes functions which require V2.00 microcode or higher.
.
- Clock Control Key Command (see "Clock Control Key Command")
- :5&mdash.Set Time-of-Day Clock
- Custom Function Routine Key Command (see "Custom Function Routine Key Command")
- Data Control Key Commands (see "Data Control Key Commands")
- :A&mdash.Automatic Transaction Build
- :W&mdash.Write Data from Source to Target
- ;7&mdash.Append Data to User Variable Data Strings
- Bar Code/Magnetic Data Input Key Commands (see "Bar Code/Magnetic Data Input Key Commands")
- :1&mdash.Fixed Length Badge Read with Validation
- :4&mdash.Alphanumeric Keys or Badge Read with Validation
- :R&mdash.Read Data with Validation
- ;1&mdash.Read Variable Length Badge
- DI/DO Key Commands (see "DI/DO Key Commands")
- :7&mdash.Toggle DO Point 0
- :M&mdash.Read Value of DI/DO Point
- :N&mdash.Wait DI Point
- :P&mdash.Write DO Point
- Display Key Commands (see "Display Key Commands")
- :0&mdash.Display Message from Message File
- :6&mdash.Display Message
- :E&mdash.Show Message
- :T&mdash.Clear Display
- :U&mdash.Set Cursor Position
- ;5&mdash.Read Display Buffer
- Keypad Input Key Commands (see "Keypad Input Key Commands")
- :2&mdash.Numeric Keypad Input
- :3&mdash.Alphanumeric Keypad Input
- Operator Indicator Key Command (see "Operator Indicator Key Command")
- ;C&mdash.Activate Selected Operator Indicator
- Transaction Control Key Commands (see "Transaction Control Key Commands")
- :8&mdash.Link Function
- :9&mdash.NO-OP
- :D&mdash.Delay
- :G&mdash.*Goto
- :GS&mdash.*Gosub
- :L&mdash.*Program Label
- :Z&mdash.*Onkey Goto
- :ZS&mdash.*Onkey Gosub
- ;0&mdash.Hot Key
- ;2&mdash.Latching Function
- ;6&mdash.Do Not Transmit
- ;A&mdash.Alias Transaction ID
- ;N&mdash.*Test User Variable
- ;R&mdash.*Return from Transaction Program Subroutine
- User Variable Key Commands (see "User Variable Key Commands")
- :F&mdash.Append Data
- :H&mdash.Clear Selected User Variable or Transaction Record
- :J&mdash.*Format User Variable
- :K&mdash.Verify Selected User Variable