ALRM_ALL_EVENTS (IDS)

onconfig.std value
0
if value not present
No effect
range of values
0 or 1
takes effect
When the database server is initialized
refer to
IBM Informix: Administrator's Reference

The ALRM_ALL_EVENTS configuration parameter is used to alter the default behavior of the ALARMPROGRAM script. When this configuration parameter is set to 1, ALARMPROGRAM will run for all events that are logged in the MSGPATH and email is sent to the administrator including relevant information about the event.